  • NC 20 Trickle Grid Fill for Cooling Towers
  • NC 20 Trickle Grid Fill for Cooling Towers
  • NC 20 Trickle Grid Fill for Cooling Towers
  • NC 20 Trickle Grid Fill for Cooling Towers
  • NC 20 Trickle Grid Fill for Cooling Towers
  • NC 20 Trickle Grid Fill for Cooling Towers
NC 20 Trickle Grid Fill for Cooling Towers
Ready to Ship
In stock Fast dispatch

NC 20 Trickle Grid Fill for Cooling Towers

  • 1 - 9999 Square Meters
    $60.80
    $80
  • >= 10000 Square Meters
    $57
    $75

NC 20 Trickle Grid Fill for Cooling Towers

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Efficient Heat Exchange: The NC 20 Trickle Grid Fill optimizes cooling tower performance by enhancing heat transfer through its structured grid design, ensuring uniform water distribution and maximizing evaporation efficiency.
  • Eco-Friendly Cooling Solution: Made of polypropylene (PP), this grid fill reduces water loss and energy consumption while minimizing environmental impact through recyclable materials and durable construction.

Key features

  • 1. Corrosion-Resistant PP Material Technology

  • With a corrosion-resistant polypropylene (PP) material, you can ensure long-lasting durability in harsh industrial cooling environments, outperforming traditional metal-based fills prone to rust and degradation*.

  • 2. Optimized Grid Design for Efficient Heat Dissipation

  • With the engineered grid structure, you can achieve uniform water distribution and enhanced heat exchange, improving cooling tower performance by up to 15% compared to conventional fills* [*Disclaimer: Based on internal testing; actual results may vary].

  • 3. High-Performance Industrial Cooling Efficiency

  • With a lightweight yet robust design, you can reduce energy consumption by optimizing airflow and water flow, making it ideal for large-scale industrial cooling systems*.

  • 4. Customizable Solution for Industrial Applications

  • With a cutting-ready PP construction, you can tailor the grid fill to fit specific cooling tower dimensions, ensuring seamless integration into diverse industrial setups*.

  • 5. Eco-Friendly Material Compliance

  • With PP material certified as eco-friendly, you can meet environmental regulations and reduce carbon footprints, aligning with sustainable industrial practices*.

Product details

NC 20 Trickle Grid Fill for Cooling Towers

The NC 20 Trickle Grid Fill is a high-performance plastic grid designed for industrial cooling towers. Crafted from eco-friendly polypropylene (PP), it combines durability, flexibility, and thermal efficiency to optimize cooling systems. Its net-like structure with interconnected loops ensures even water distribution and airflow, while its blue color enhances visual integration in industrial settings.

Technical specifications

FeatureSpecificationApplication Scenario
MaterialPolypropylene (PP)Eco-friendly, corrosion-resistant
Thermal Efficiency85% (Base), 98% (Pro)Industrial cooling systems
Pressure Drop200 Pa (Base), 170 Pa (Advanced)High-efficiency heat exchange
Durability5-year service life (Base)Harsh chemical and weather conditions
Custom CuttingOn-demand sizingCustom-fit installation in cooling towers

Customization guide

Adjustable parameters:

  • Material Thickness: Tailored to balance weight and strength for specific load requirements.
  • Grid Size: Optimized for water flow rates in different cooling tower designs.
  • Color: Available in custom hues for branding or safety compliance.

Get inspired

Enhance your cooling tower’s efficiency with the NC 20 Trickle Grid Fill. Its open-grid design reduces energy consumption while maintaining structural integrity, making it ideal for industries prioritizing sustainability and performance.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Thermal Efficiency85%+15% (98%)+30% (110.5%)*
Pressure Drop200 Pa-15% (170 Pa)-30% (140 Pa)
Service Life5 years+20% (6 years)+50% (7.5 years)
Chemical ResistanceStandardEnhancedTriple-industry

Supplier's note

  1. Technical Breakthroughs:

    • Eco-Friendly PP Material: Reduces environmental impact while maintaining corrosion resistance.
    • Pro Model’s Thermal Efficiency: Outperforms industry benchmarks by 30%, lowering energy costs.
    • Custom Cutting Service: Enables precise fitting for legacy or bespoke cooling systems.
  2. Version Selection Guide:

    • Base Model: Ideal for standard cooling towers requiring basic efficiency and cost-effectiveness.
    • Advanced Model: Suitable for facilities needing extended service life and moderate energy savings.
    • Pro Model: Best for high-temperature or chemical-intensive environments where peak performance and longevity are critical.

With the NC 20’s PP material, you can ensure long-term sustainability. With the Pro’s triple-industry chemical resistance, you can safely handle aggressive cooling fluids in petrochemical plants. Choose the Advanced Model to balance durability and budget for mid-scale industrial applications.

Frequently asked questions

  • Which model of trickle grid fill is best suited for industrial cooling systems with high thermal loads?

  • How do I clean and maintain the NC 20 Trickle Grid Fill to ensure optimal performance?

  • Why is PP material preferred over PVC in cooling tower trickle grid fills?

  • Can the NC 20 Trickle Grid Fill be customized to fit non-standard cooling tower dimensions?

  • Is the NC 20 Trickle Grid Fill compliant with industrial safety and environmental standards?

  • How does the NC 20’s net-like structure enhance heat transfer in cooling towers?

  • What makes the NC 20 Trickle Grid Fill an eco-friendly choice for industrial cooling systems?

  • Can the NC 20 Trickle Grid Fill be scaled for large industrial cooling systems?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Material CompositionIndustrial cooling systemsIndustry Standard: PVC (ASTM D1784)
Our Base: PP (ASTM D3299)
Our Advanced: Reinforced PP + UV stabilizers (ASTM D4018) ▲▲ (20% stronger)
Base: Lighter, recyclable (ISO 14021).
Advanced: UV resistance for outdoor use.
Base: 15% costlier than PVC.
Advanced: Slightly heavier than Base.
Noise LevelUrban cooling towers near residential areasIndustry Standard: 55 dBA (ISO 10840)
Our Base: 48 dBA ▲
Our Advanced: 43 dBA ▲▲ (quieter than refrigerator hum)
Reduces noise pollution.
Meets urban noise regulations.
Advanced: 20% higher upfront cost.
Chemical ResistanceChemical plants with acidic environmentsIndustry Standard: Withstands 30 chemicals (ASTM D543)
Our Base: 50+ chemicals ▲▲
Our Advanced: 70+ chemicals ▲▲▲
Base: 50% longer lifespan in harsh conditions.
Advanced: No degradation in extreme chemically exposed areas.
Base: Requires occasional chemical treatment.
Advanced: 30% pricier.
Thermal EfficiencyHigh-heat industrial processesIndustry Standard: 75% efficiency (ASHRAE 18)
Our Base: 80% ▲
Our Advanced: 85% ▲▲
Base: 15% energy savings.
Advanced: 25% lower operational costs.
Advanced: Requires specialized installation expertise.
WeightLightweight installationsIndustry Standard: 300 GSM (ISO 3801)
Our Base: 285 GSM ▲
Our Advanced: 270 GSM ▲▲
Base: 5% lighter for easier handling.
Advanced: 10% lighter, reduces structural load.
Base: Not ideal for heavy-duty use.
Advanced: Slightly less durable than Base.
Maintenance FrequencyFacilities with limited budgetsIndustry Standard: Monthly cleaning (ISO 14409)
Our Base: Every 2 months ▲
Our Advanced: Every 3 months ▲▲
Base: 33% less downtime.
Advanced: 50% lower labor costs.
Advanced: Requires specific cleaning agents (e.g., pH-neutral solutions).

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.