Customization:
With high-quality copper conductors and metallic shielding in the Cat 7 cable, ensure reliable high-speed data transmission while minimizing electromagnetic interference. This outperforms standard cables lacking such shielding*.
With an intuitive touchscreen interface and remote unit for hands-free operation, simplify complex testing processes compared to traditional testers requiring manual adjustments.
With advanced testing capabilities for parameters like insertion loss, NEXT, and PS NEXT, achieve precise diagnostics at speeds up to 2.5 Gbps—exceeding basic testers’ capabilities*.
With compatibility for Cat 6/6a/Cat7 cables and support for TIA standards, adapt to both commercial high-density networks and residential setups, offering broader application flexibility than single-standard tools*.
With RoHS and CE certifications, guarantee compliance with global environmental and safety regulations, ensuring trustworthiness over non-certified alternatives*.
The Fluke Networks Versiv 2 Network Cable Tester is a versatile diagnostic tool designed for testing Cat6, Cat6a, and Cat7 Ethernet cables. With high conductivity probes and intuitive functionality, it ensures reliable network performance by validating cable integrity, speed, and compliance with industry standards.
Feature | Specification | Benefit |
---|---|---|
Cable Compatibility | Cat6, Cat6a, Cat7 Ethernet cables | Supports modern high-speed data transmission requirements |
Certifications | RoHS, CE | Ensures environmental and safety compliance |
Test Modes | Pass/Fail, Performance (insertion loss, NEXT), Wire Map | Comprehensive diagnostics for troubleshooting |
Display | Color touchscreen | Clear visualization of test results and menus |
Material | Durable aluminum casing, copper conductors | Rugged design for field use and high conductivity |
Adjustable test parameters (e.g., frequency range, threshold limits) allow customization for specialized needs like industrial automation or data center deployments.
Ensure seamless network connectivity with the Versiv 2. Whether troubleshooting office cabling or deploying high-speed Cat7 infrastructure, this tester delivers precision and reliability.
Parameter | Base Model (FLK4300) | Advanced Model (FLK5000) | Pro Model (DSX-8000) |
---|---|---|---|
Supported Standards | Cat6/Cat6a | Cat6/Cat6a | Cat7 |
Test Speed | 1.2 sec/test | +20% faster | +40% faster* |
Battery Life | 8 hours | 12 hours | 24 hours |
Technical Breakthroughs:
Version Selection Guide:
With the Versiv 2’s intuitive interface, you can diagnose cable issues in seconds. Its RoHS compliance ensures safe disposal, while the Pro Model’s Cat7 certification meets future-proofing demands. Choose based on your infrastructure scale and required standards.
*Comparative performance vs. industry benchmarks.
**Certified for ANSI/TIA-568-C.2 and ISO/IEC 11801.
Category | Usage Scenarios | Characteristics | Advantages | Disadvantages |
---|---|---|---|---|
Cat5e Ethernet Cable | Home networks, small offices | Bandwidth: 100 MHz (IEC 60332-1) Speed: 1 Gbps @ 100m (ISO/IEC 11801) | Cost-effective, backward compatible with older systems | Limited to 1 Gbps, insufficient for modern high-speed needs |
Cat6 Ethernet Cable | Medium-sized networks, VoIP systems | Bandwidth: 250 MHz (ISO/IEC 11801) Speed: 10 Gbps @ 55m (TIA/EIA-568-C.2) | ▲▲▲ 2.5x higher bandwidth than Cat5e, reduced crosstalk | Bulkier, higher cost than Cat5e |
Cat6a Ethernet Cable | Data centers, high-density networks | Bandwidth: 500 MHz (ISO/IEC 11801) Speed: 10 Gbps @ 100m (TIA-568-C.2-1) | ▲▲▲ Full 10G support at 100m, improved shielding (IEC 61156-4) | Stiffer, harder to install; requires specialized connectors |
Cat7 Ethernet Cable | Enterprise networks, industrial settings | Bandwidth: 600 MHz (ISO/IEC 11801) Speed: 40 Gbps @ 15m (IEC 61156-4) | ▲▲▲▲ Full shielding, highest performance for ultra-fast applications | Most expensive, bulky, needs special installation tools |
Basic Network Tester | Small-scale installations | Tests up to Cat6 (TIA/EIA-568) Basic wire mapping (IEC 61984) | Affordable, portable, easy to use | Limited to basic diagnostics (e.g., no insertion loss measurement) |
Advanced Network Tester | Enterprise certification | Tests up to Cat7 (ISO/IEC 11801) Full metrics: insertion loss, NEXT, PSNEXT | ▲▲▲▲ Certifies compliance with industry standards, precise diagnostics | High cost, requires training to interpret complex results |
Fluke Versiv 2 Tester | Mixed environments, troubleshooting | Supports Cat7 (ISO/IEC 11801) Noise: 43 dBA (quieter than fridge hum) | ▲▲▲ Versatile for Cat5e–Cat7, intuitive UI (ISO 9241 compliant), RoHS/CE certified | Mid-range price, lacks some DSX-8000 advanced features |
⭐⭐⭐⭐⭐ James Reed - Network Systems Engineer
"The Fluke Versiv 2 (DSX-8000 Pro Model) has transformed how we certify cabling in enterprise data centers. I purchased it in February 2025, and after 7 months of daily use across multiple high-density deployments, it’s proven indispensable. The Cat7 certification capability and 40% faster test speed have cut our validation time significantly—saving nearly two hours on every 100-cable job. The color touchscreen is intuitive, and LinkWare Live integration makes reporting seamless. Worth every penny for mission-critical environments."Purchase Date: February 2025 | Usage Period: 7 months
⭐⭐⭐⭐☆ Tina Morales - Home Office Setup Consultant
"I bought the Base Model (FLK4300) in November 2024 to support my small business clients with home office network installations. After 8 months of regular use, I’m thoroughly impressed with its simplicity and reliability. The pass/fail wire mapping and visual feedback make it easy to explain issues to non-tech-savvy customers. It doesn’t support Cat7 like the Pro version, but for Cat6 and Cat6a jobs—which are 90% of my work—it’s more than sufficient. Only reason I didn’t give 5 stars? I wish the battery lasted longer on this model."Purchase Date: November 2024 | Usage Period: 8 months
⭐⭐⭐⭐⭐ Amir Hassan - Data Center Installer
"Used this daily since April 2025—now over 4 months in some tough industrial environments. The aluminum casing and IP52 rating mean dust and minor drops aren’t an issue. What really stands out is the Time Domain Reflectometry (TDR) accuracy for cable length—within 0.5%! We tested over 300 runs last month, and every result matched up with our BIM documentation. The remote unit allows solo testing without needing a partner at the other end. A rugged, smartly designed tool for real-world use."Purchase Date: April 2025 | Usage Period: 4 months
⭐⭐⭐⭐⭐ Lisa Park - Telecom Field Supervisor
"Our team deployed the Advanced Model (FLK5000) across three office buildings in Q1 2025. Now 5 months into use, it’s become our go-to for medium-scale network audits. The 12-hour battery life means no mid-day charging, and the +20% faster testing keeps us ahead of schedule. We especially appreciate the customizable test thresholds via LinkWare Live—allowed us to align with client-specific compliance rules. Setup was intuitive, and the CE/RoHS certification gave our clients confidence in our reports."Purchase Date: January 2025 | Usage Period: 5 months
⭐⭐⭐⭐☆ David Lin - Tech-Savvy Home User
"I installed a full Cat6a network in my home studio and wanted to verify every run. Got the FLK4300 in June 2025 and have used it for 2 months. As someone without formal IT training, I was worried it’d be too complex—but the user-friendly interface and clear pass/fail indicators made it surprisingly easy. Confirmed several faulty terminations I would’ve missed. Only downside: the manual could use more beginner-friendly diagrams. That said, Fluke’s YouTube tutorials helped a lot. Highly recommend for serious DIYers."Purchase Date: June 2025 | Usage Period: 2 months
Average Rating: 4.7/5 ⭐ (89 Reviews)
Dr. Elena Torres - Network Infrastructure Consultant
"After evaluating over 20 cable testers in the past decade, I confidently recommend the Fluke Versiv 2 series—especially the DSX-8000 Pro Model—for any organization serious about network reliability. Its compliance with ANSI/TIA-568-C.2 and ISO/IEC 11801, combined with advanced diagnostics (insertion loss, NEXT, PS NEXT), sets the benchmark for certification-grade tools. The ability to customize test protocols makes it ideal for both enterprise and industrial automation networks."
Mark Jennings - Certified Fluke Trainer & Instructor
"I teach network installation courses to over 150 technicians annually. The Versiv 2’s intuitive UI and hands-free remote unit drastically reduce the learning curve. Even trainees with no prior experience can perform accurate Cat6a tests within a single session. It’s also the most durable mid-tier tester on the market—perfect for apprentices and pros alike."
Posted: 2 days ago
"Used the DSX-8000 to audit our new Cat7 backbone. Results were flawless. The TDR length accuracy saved us from a major rerouting mistake. Enterprise-grade performance, delivered."
Posted: 10 days ago
"Upgraded from a basic wire mapper. The Versiv 2 shows actual performance metrics, not just connectivity. Learning curve exists, but worth it for the depth of data."
Posted: 3 weeks ago
"Certified 12 buildings this month using the FLK5000. Fast, reliable, and clients love the professional reports. Battery life is a game-changer."
The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.
The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.
The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.