  • OMS-560 Elevator Load Measurement Controller OMS-520 Elevator Load Weighing Sensor Cell Price
  • OMS-560 Elevator Load Measurement Controller OMS-520 Elevator Load Weighing Sensor Cell Price
  • OMS-560 Elevator Load Measurement Controller OMS-520 Elevator Load Weighing Sensor Cell Price
  • OMS-560 Elevator Load Measurement Controller OMS-520 Elevator Load Weighing Sensor Cell Price
  • OMS-560 Elevator Load Measurement Controller OMS-520 Elevator Load Weighing Sensor Cell Price
  • OMS-560 Elevator Load Measurement Controller OMS-520 Elevator Load Weighing Sensor Cell Price
OMS-560 Elevator Load Measurement Controller OMS-520 Elevator Load Weighing Sensor Cell Price

OMS-560 Elevator Load Measurement Controller OMS-520 Elevator Load Weighing Sensor Cell Price

$45.00-$95.00/ Set|1 Set/Sets(Min. Order)

Customization:

Customized logo(Min.Order: 1000 pieces)
Customized packaging(Min.Order: 5000 pieces)
Graphic customization(Min.Order: 1000 pieces)

OMS-560 Elevator Load Measurement Controller OMS-520 Elevator Load Weighing Sensor Cell Price

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Load Measurement & Control (OMS-560): Precision elevator load measurement controller designed to monitor and regulate elevator weight in real-time, ensuring safety and compliance with capacity limits.
  • High-Accuracy Sensing (OMS-520): Industrial-grade weighing sensor cell that detects and transmits load data to the controller, enabling dynamic weight analysis for elevators.

Key features

  • 1. Durable Material Construction

  • With a robust plastic housing, ensure reliable operation in industrial environments while maintaining lightweight durability. This material choice offers superior resistance to environmental stress compared to heavier metal alternatives*.

  • 2. User-Friendly Interactive Design

  • With an intuitive LCD display and color-coded control buttons (gray, red, green), simplify configuration and real-time monitoring. The clear labeling reduces misconfiguration risks, outperforming less user-centric interfaces*.

  • 3. High-Precision Load Measurement Technology

  • With multi-terminal output capabilities (COM0-COM2) and precise input sensors (X01, AV+/AV-), achieve accurate weight readings critical for elevator safety. This ensures smoother operation compared to basic load sensors*.

  • 4. Modular Adaptability for Diverse Scenarios

  • With a modular design supporting customizable input/output configurations, seamlessly integrate into commercial elevators or hotel systems. This flexibility exceeds fixed-design controllers in multi-application setups*.

  • 5. Compliance with Safety Standards

  • With adherence to industry safety certifications (e.g., ISO/IEC standards for elevator components), prioritize safety and reliability in regulated environments. Confirm compliance details directly with the manufacturer.

Product details

OMS-560 Elevator Load Measurement Controller OMS-520 Elevator Load Weighing Sensor Cell Price

The OMS-560/520 elevator load measurement system combines durable construction with modular design to ensure precise weight monitoring in elevators and hotel applications. Its user-friendly interface and customizable I/O terminals enable seamless integration into diverse systems.

Technical specifications

FeatureSpecificationApplication Scenario
MaterialDurable plastic housingWithstands harsh industrial environments
Input Channels8 digital inputs (X01, AV+, AS+, etc.)Connects sensors for load detection
Output Channels3 COM ports (COM0-COM2)Controls elevator mechanisms
DisplayLCD status displayReal-time monitoring of load data
CertificationsCE, UL (Base); ISO 9001 (Pro)Meets global elevator safety standards

Customization guide

Adjustable parameters include:

  • I/O Terminal Expansion (add up to 16 channels for complex systems)
  • Material Thickness (customized for extreme temperature ranges)
  • Interface Colors (recode buttons to match facility branding)

Get inspired

Optimize elevator safety and efficiency with the OMS-560/520. Its modular design allows rapid adaptation to hotel elevators requiring high-capacity load monitoring or industrial systems needing rugged durability.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Channel Capacity8 inputs/3 outputs12 inputs/5 outputs16 inputs/8 outputs*
Max Load Capacity5,000 kg8,000 kg12,000 kg
CertificationsCECE + ISO 9001CE + UL + ISO 9001
Display Resolution128x64 pixels256x128 pixels320x240 pixels

Supplier's note

  1. Technical Breakthroughs:

    • Modular Design: Enables field-upgradeable I/O ports (20% faster installation than fixed systems).
    • High Load Accuracy: ±0.5% error margin (3x better than industry benchmarks).
    • Rugged Material: Withstands -20°C to 70°C (outperforming plastic-only competitors).
  2. Version Selection Guide:

    • Base Model: Ideal for standard residential elevators with ≤5,000 kg loads.
    • Advanced Model: Best for hotels needing 8,000 kg capacity and ISO compliance.
    • Pro Model: Required for industrial/commercial elevators handling 12,000 kg loads. Its UL certification ensures compatibility with global safety standards.

*Pro Model supports daisy-chaining for large-scale elevator networks.

Frequently asked questions

  • Which model suits elevators in hotels?

  • How to clean the OMS-560’s control panel?

  • Plastic vs Metal for elevator load sensors: Which is better?

  • Can OMS-520 sensors be customized for specific loads?

  • Are OMS-560 controllers CE-certified?

  • Compatibility with different elevator brands?

  • Installation steps for OMS-560?

  • Warranty for elevator load measurement systems?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Material & DurabilityHigh-traffic elevators in hotelsIndustry: Basic plastic (ASTM D638, 5,000 cycles)
Our Base: Reinforced plastic (ASTM D638, 7,000 cycles )
Our Advanced: Ultra-durable composite (ASTM D638, 10,000 cycles ▲▲)
Extended lifespan in corrosive or high-wear environmentsAdvanced materials may increase upfront cost
Noise LevelQuiet environments (e.g., hospitals)Industry: 50 dB (louder than office chatter)
Our Base: 45 dB (quieter than office noise )
Our Advanced: 40 dB (similar to library ambient noise ▲▲)
Minimizes disruption in sensitive settingsAdvanced models may require more power to maintain performance
Input/Output CapacityComplex elevator systems with sensorsIndustry: 8 input channels
Our Base: 12 channels
Our Advanced: 16 channels ▲▲
Supports integration with advanced safety systems and IoT devicesHigher channel count may demand specialized technician training
CertificationsGlobal elevator installationsIndustry: ISO 9001
Our Base: ISO 9001 + CE
Our Advanced: ISO 9001 + CE + UL ▲▲
Wider compliance opens access to international marketsCompliance testing adds to development time and cost
Weight & PortabilityRetrofitting existing elevator systemsIndustry: 2.5 kg
Our Base: 2.2 kg
Our Advanced: 2.0 kg ▲▲
Easier installation and reduced labor costsLighter materials may require thicker coatings to maintain durability
User InterfaceMaintenance by non-specialistsIndustry: Basic LCD (1.5", monochrome)
Our Base: 2" color LCD + tactile buttons
Our Advanced: 3" touchscreen + color-coded buttons ▲▲
Reduces training time and lowers error ratesAdvanced interfaces may have higher failure rates due to complexity

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.