All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier

R245fa R123 Low Pressure Refrigerant Recovery Charging Machine 2HP Air Cooled Recovery Unit AC Recharge Machine

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Refrigerant Recovery & Charging: Designed to efficiently recover and recharge low-pressure refrigerants (R245fa, R123) for HVAC systems, ensuring environmental compliance and resource reuse.
  • Air-Cooled Cooling System: Equipped with a 2HP air-cooled recovery unit for optimal thermal management, suitable for low-pressure refrigerant handling in industrial and commercial settings.

Key features

  • 1. Corrosion-Resistant Metal Construction

  • With a durable steel/aluminum body, ensure long-term reliability in harsh industrial environments. Outlasting plastic-based models by up to 30%* in corrosion resistance, this unit withstands extreme temperatures and chemical exposure.

  • 2. Intuitive Control Panel Design

  • With a multifunctional control panel, operators can monitor real-time temperature, pressure, and system status via gauges and adjust settings via dedicated buttons. This simplifies troubleshooting compared to manual systems*.

  • 3. High-Capacity 2HP Performance

  • With a 2HP air-cooled motor, achieve rapid refrigerant recovery and charging speeds—up to 20% faster than standard 1.5HP models*. Efficiently handle large-scale cooling demands in commercial or industrial settings.

  • 4. Customizable Industrial Solutions

  • With modular valves and connections, adapt to diverse refrigerant types (e.g., R245fa/R123) and integrate seamlessly into existing systems. Ideal for 24/7 operation in manufacturing or data centers versus intermittent home-use units*.

  • 5. Compliance with Safety Standards

  • With approved refrigerants and safety-rated components, meet industrial safety and environmental regulations (e.g., OSHA, ISO). Red accents and emergency shutdown buttons enhance workplace safety compared to non-certified alternatives*.

Product details

R245fa R123 Low Pressure Refrigerant Recovery Charging Machine 2HP Air Cooled Recovery Unit AC Recharge Machine

The R245fa R123 Low Pressure Refrigerant Recovery Charging Machine is a robust industrial refrigeration unit designed for efficient refrigerant recovery, charging, and system maintenance. Built with corrosion-resistant metal (steel/aluminum), it features a user-friendly control panel, customizable valve configurations, and advanced safety mechanisms. Ideal for HVAC technicians and industrial facilities, this air-cooled recovery unit ensures compliance with global standards while offering scalable performance.

Technical specifications

FeatureSpecificationApplication Scenario
Refrigerant CompatibilityR245fa, R123 (Low Pressure)Recovery and charging in HVAC systems
Cooling Capacity2HP Air-Cooled SystemHeat dissipation in industrial settings
Material ConstructionSteel/Aluminum (Corrosion-Resistant)Harsh outdoor or industrial environments
Control PanelButtons, Gauges, Emergency Shut-OffReal-time monitoring and safety control
Valves/ConnectionsModular Design (Customizable Ports)Flexible integration with diverse systems
Safety StandardsISO 13478 ComplianceHigh-risk industrial operations

Customization guide

Adjustable valve configurations and modular port arrangements allow customization to meet specific refrigerant flow requirements or system integration needs. The unit’s open design supports tailored modifications for specialized applications.

Get inspired

Whether maintaining commercial HVAC systems or managing industrial cooling networks, this recovery unit combines durability and precision. Its safety-first design and adaptable features empower technicians to tackle complex refrigerant management tasks efficiently.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Cooling Efficiency2HP Standard+15% Enhanced Cooling+30% Ultra-Efficient *
Pressure Range0-15 psi0-20 psi Extended0-25 psi Wide Range
Safety FeaturesBasic ISO 13478Dual Redundant SafetiesTripled Chemical Resistance*
Warranty1 Year2 Years3 Years

Supplier's note

  1. Technical Breakthroughs:

    • Tripled Chemical Resistance (Pro Model): Enables safe handling of corrosive refrigerants in chemical plants.
    • Extended Pressure Range (Advanced/Pro): Supports high-demand systems like data centers.
    • Modular Valve Design: Reduces downtime by simplifying system integration.
  2. Optimal Version Selection:

    • Base Model: Ideal for small workshops or routine HVAC maintenance where standard pressure and basic safety suffice.
    • Advanced Model: Suitable for medium-scale industrial facilities requiring extended pressure handling and enhanced safety.
    • Pro Model: Designed for heavy-duty applications (e.g., chemical processing plants) needing extreme durability and compliance with严苛 standards.

With the Pro’s tripled chemical resistance, you can safely recover corrosive refrigerants in hazardous environments. Pair its wide pressure range with modular ports to create a seamless integration with legacy systems. The Base Model’s 2HP efficiency ensures cost-effective performance for everyday use.

*Denotes improvement over industry benchmarks.

Frequently asked questions

  • Which refrigerant recovery machine is best suited for low-pressure systems like R245fa and R123?

  • How do I maintain the valves on an industrial refrigerant recovery unit?

  • Is the R245fa recovery unit compliant with industry safety standards?

  • Can this recovery machine be customized for specific refrigerant types?

  • What safety features does the R245fa recovery unit include?

  • What’s covered under the 1-year warranty for this refrigerant recovery machine?

  • What cooling capacity does the 2HP air-cooled recovery unit provide?

  • How does the air-cooled design benefit refrigerant recovery processes?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Cooling CapacityIndustrial Plants, Data CentersIndustry: 1.5HP (IEC 60034)
Our Base: 2HP (▲)
Our Advanced: 2.5HP (▲▲)
Handles large-scale cooling demands (▲▲▲)
IEC 60034 efficiency class IE3
Higher energy consumption (▲▲)
Noise LevelOffice Buildings, HospitalsIndustry: 50 dBA (▲)
Our Base: 45 dBA (▲▲)
Our Advanced: 40 dBA (▲▲▲)
Quieter than a refrigerator (40 dB vs typical 45 dB)
ISO 1996 compliance
Requires premium insulation for ultra-quiet operation (▲▲)
Safety FeaturesHazardous Material FacilitiesIndustry: Basic labels
Our Base: Emergency shutoff (▲)
Advanced: Pressure sensors + alarms (▲▲)
Meets OSHA standards (▲▲)
Auto-shutoff in overpressure scenarios
Advanced models add $500 to cost (▲)
Customization OptionsCustom Installation ProjectsIndustry: 3 ports
Our Base: 5 ports (▲)
Advanced: 8 ports (▲▲)
ISO 5149-compatible ports for flexible integration (▲▲)
Supports 10+ fluids
Advanced models require specialized installation training (▲)
Warranty PeriodLong-Term ContractsIndustry: 1 year
Our Base: 1 year (same)
Advanced: 2 years (▲)
Extended coverage for critical infrastructure (▲)Base model lacks extended coverage for high-risk environments (▲)
Material DurabilityHarsh Outdoor EnvironmentsIndustry: Standard steel (ASTM A36)
Our Base: Corrosion-resistant steel (▲)
Advanced: Aluminum plating (▲▲)
Passes ASTM A365 corrosion tests (▲▲)
Resists saltwater exposure (▲▲)
Advanced models 20% heavier for structural reinforcement (▲)

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.