All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier
  • Renke High Precision Nitrogen Modbus Sensor N2 Nitrogen Gas Detector Price
  • Renke High Precision Nitrogen Modbus Sensor N2 Nitrogen Gas Detector Price
  • Renke High Precision Nitrogen Modbus Sensor N2 Nitrogen Gas Detector Price
  • Renke High Precision Nitrogen Modbus Sensor N2 Nitrogen Gas Detector Price
  • Renke High Precision Nitrogen Modbus Sensor N2 Nitrogen Gas Detector Price
Renke High Precision Nitrogen Modbus Sensor N2 Nitrogen Gas Detector Price
Ready to Ship
In stock Fast dispatch

Renke High Precision Nitrogen Modbus Sensor N2 Nitrogen Gas Detector Price

$95.00-$101.00/ Piece|1 Piece/Pieces(Min. Order)

Customization:

logo(Min.Order: 100 pieces)

Renke High Precision Nitrogen Modbus Sensor N2 Nitrogen Gas Detector Price

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • High Precision Nitrogen Measurement: Detects nitrogen (N₂) concentration in gas streams with an accuracy of 0.1%vol, ensuring reliable real-time monitoring.
  • Modbus Data Transmission: Transmits measurement data via wired Modbus protocol for seamless integration into industrial control systems or remote monitoring platforms.

Key features

  • 1. Corrosion-Resistant Material Technology

  • With a robust, corrosion-resistant plastic enclosure, you can ensure durability in harsh industrial environments, such as chemical plants or outdoor installations.

  • 2. Seamless Modbus Integration

  • With built-in Modbus compatibility, you can integrate the sensor effortlessly into existing industrial control systems for real-time nitrogen concentration monitoring.

  • 3. Ultra-High Measurement Accuracy

  • With 0.1%vol accuracy, you can achieve precise nitrogen concentration measurements, minimizing errors in critical applications like gas blending or safety monitoring.

  • 4. Flexible Industrial Installation

  • With wall-mount design and pre-drilled mounting holes, you can install the sensor quickly in confined spaces or elevated locations without additional hardware.

  • 5. IP65 Weatherproof Protection

  • With an IP65-rated enclosure, you can deploy the sensor in dusty or humid environments while maintaining reliable operation.

Product details

Renke High Precision Nitrogen Modbus Sensor N2 Nitrogen Gas Detector Price

The Renke High Precision Nitrogen Modbus Sensor N2 is a rugged, wall-mountable gas detector designed for precise measurement and transmission of nitrogen (N₂) concentration in industrial gas streams. Built with a weatherproof plastic enclosure and customizable output protocols, it ensures reliability in harsh environments while offering scalable performance through three model tiers.

Technical specifications

FeatureSpecificationBenefit
Accuracy±0.1% vol (0-100% vol range)Ensures precise measurements in critical applications
MaterialCorrosion-resistant plasticWithstands chemicals, moisture, and dust
Mounting OptionsPre-drilled top/bottom holesEasy wall or bracket installation
Output ProtocolsModbus RTU, 4-20mA, 0-10VFlexible integration with control systems
Sensor TypeInfrared (IR) gas detectionStable performance in high-temperature environments
Operating Temp.-20°C to 60°CReliable in extreme industrial conditions

Customization guide

Adjustable parameters include:

  • Measurement Range: Customize from 0-10% vol to 0-100% vol to match specific gas stream concentrations.
  • Output Protocol: Choose between Modbus, 4-20mA, or 0-10V for seamless system compatibility.
  • Alarm Thresholds: Set user-defined alerts for real-time safety monitoring.

Get inspired

Optimize gas monitoring in industrial plants, laboratories, or HVAC systems with the Renke N₂ Transmitter. Its robust design and precise Modbus communication ensure reliable data transmission, while adjustable parameters let you tailor it to your workflow.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
Accuracy±0.1% vol±0.05% vol±0.02% vol
Response Time15 sec10 sec5 sec*
Max Operating Pressure10 bar20 bar30 bar
CertificationsCE, RoHSCE, RoHS, ATEXCE, RoHS, ATEX, IECEx

Supplier's note

  1. Technical Breakthroughs:

    • Precision: The Pro Model’s ±0.02% vol accuracy (triple the Base Model’s resolution) enables ultra-sensitive N₂ monitoring in semiconductor cleanrooms.
    • Durability: Corrosion-resistant housing and IP65 rating protect against harsh chemicals, extending lifespan by 20% compared to standard sensors.
    • Speed: The Pro’s 5-second response time is 66% faster than industry benchmarks, critical for rapid leak detection.
  2. Model Selection Guidance:

    • Base Model: Ideal for basic industrial monitoring (e.g., HVAC systems) where cost-efficiency is prioritized.
    • Advanced Model: Suitable for mid-tier applications requiring explosion-proof certification (ATEX) in oil/gas facilities.
    • Pro Model: Best for high-precision labs or high-pressure environments (e.g., chemical processing) needing IECEx compliance and real-time data.

*Pro Model’s response time is 66% faster than industry standards.

Frequently asked questions

  • Which nitrogen gas detector is best suited for harsh industrial environments?

  • How often should the Renke N2 sensor be cleaned to maintain accuracy?

  • Does the Renke N2 sensor require periodic calibration?

  • Can the Modbus output of the Renke N2 transmitter be customized?

  • How is the wall-mounted Renke N2 detector installed?

  • What is the detection range of the Renke High Precision Nitrogen Sensor?

  • Is the Renke N2 detector suitable for outdoor use?

  • Does the infrared N2 detector integrate with third-party systems?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
AccuracyIndustrial process control, labsIndustry Standard: ±1% vol (ISO 9001)
Our Base: ±0.3% vol (NIST-traceable)
Our Advanced: ±0.1% vol (ASTM D6667)
Advanced: 3× higher precision for critical applications ▲▲▲
Base: Cost-effective for routine monitoring ▲
Advanced: 20% higher cost vs Base ▲
Industry: Limited to non-critical monitoring
Sensor TechnologyHarsh environments (e.g., oil refineries)Industry Standard: Electrochemical sensors
Our Base/Advanced: Infrared (IR) spectroscopy (ISO 20871)
IR resists cross-gas interference ▲
Longer lifespan in corrosive settings ▲▲
Higher upfront cost vs electrochemical sensors ▲
Slower response time in low concentrations
Communication ProtocolSmart factories, IoT integrationIndustry Standard: Analog (4-20mA)
Our Base: RS-485
Our Advanced: Modbus RTU (IEC 61158)
Advanced: Plug-and-play with PLC systems ▲▲
Base: Compatible with legacy systems
Industry: No remote diagnostics ▲
Advanced: Requires gateway for cloud connectivity
Mounting TypeConfined spaces, outdoor installationsIndustry Standard: Universal brackets (IP54)
Our Base/Advanced: Wall-mounted (IP67) with vibration damping
Dust/waterproof design ▲▲
Easy retrofitting in existing infrastructure ▲
No ceiling-mount option in Base ▲
Advanced adds tilt-resistant brackets ▲▲
Environmental ResistanceChemical plants, marine environmentsIndustry Standard: IP54 (dust/water resistance)
Our Base: IP65
Our Advanced: IP68 (immersion-proof)
Advanced: Survives accidental submersion ▲▲▲
Base: Meets OSHA standards ▲
Advanced: 30% heavier ▲
Industry: Fails in high-humidity zones
Power ConsumptionBattery-operated sensors, remote sitesIndustry Standard: 5W (continuous)
Our Base: 3W (sleep mode enabled)
Our Advanced: 1.5W (IoT-optimized)
Advanced: 72-hour battery life ▲▲▲
Base: 40% lower energy use vs Industry ▲
Industry: Frequent maintenance for battery replacement ▲
Advanced: Requires Li-ion battery ▲

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.