All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier
  • Stranded Copper Wire of lightning Rod Ground Wire
  • Stranded Copper Wire of lightning Rod Ground Wire
  • Stranded Copper Wire of lightning Rod Ground Wire
  • Stranded Copper Wire of lightning Rod Ground Wire
  • Stranded Copper Wire of lightning Rod Ground Wire
  • Stranded Copper Wire of lightning Rod Ground Wire
Stranded Copper Wire of lightning Rod Ground Wire

Stranded Copper Wire of lightning Rod Ground Wire

$0.50-$5.00/ Meter|100 Meter/Meters(Min. Order)

Customization:

Customized logo(Min.Order: 100 pieces)
Customized packaging(Min.Order: 100 pieces)

Stranded Copper Wire of lightning Rod Ground Wire

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Lightning Protection & Grounding: Designed to safely conduct electrical surges from lightning rods to the ground, ensuring protection for buildings and infrastructure.
  • Multi-Strand Conductivity: Features a stranded copper core (1.4mm single wire size) for optimal electrical conductivity, flexibility, and resistance to corrosion, ideal for underground and cable applications.

Key features

  • 1. Material Technology

  • With multi-strand copper construction, achieve superior flexibility and durability compared to solid copper wires*. This design allows safe bending in tight spaces without compromising structural integrity, ideal for complex installation scenarios.

  • 2. Performance Parameters

  • With a 1.4mm diameter and stranded design, deliver 30% higher tensile strength than standard solid wires*, ensuring reliable performance in heavy-duty electrical systems. The multi-strand structure also improves conductivity, reducing energy loss in high-load applications.

  • 3. Scenario Solutions

  • Designed for lightning protection and underground applications, this wire ensures reliable grounding in extreme weather and corrosive environments*, minimizing surge risks during storms. Its robust construction adapts to both industrial machinery and buried cable systems.

  • 4. Certification Standards

  • While specific certifications are not listed, the copper and copper-clad steel composition meets industry standards for electrical safety and durability*, as confirmed by the manufacturer. The materials resist corrosion and ensure compliance with grounding requirements.

  • 5. Electrical Conductivity & Customization

  • With high-conductivity copper material, reduce energy loss and

Product details

Stranded Copper Wire of lightning Rod Ground Wire

The Stranded Copper Wire of Lightning Rod Ground Wire is a heavy-duty electrical solution designed for industrial and underground applications. Its multi-strand construction ensures flexibility, durability, and optimal electrical conductivity, making it ideal for lightning protection systems, grounding networks, and rugged outdoor environments.

Technical specifications

FeatureSpecificationBenefit
Conductor MaterialStranded copper / Copper Clad SteelEnhanced conductivity and tensile strength
ConstructionMulti-strand (1.4mm single wire size)Flexible routing without breakage
CoatingBareDirect earth contact for efficient grounding
ApplicationUnderground cables, lightning rodsEnsures safety in harsh environmental conditions
Tensile Strength450 N/mm²Withstands mechanical stress in construction

Customization guide

Adjustable parameters include strand count (for flexibility vs. strength) and diameter (1.4mm to 3.0mm) to meet specific requirements. For corrosive environments, opt for copper-clad steel cores to balance cost and durability.

Get inspired

With its multi-strand design, this wire can bend around sharp corners without damage, while its bare surface ensures seamless grounding. Perfect for constructing robust lightning protection systems or industrial-grade underground cables.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
ConductivityIACS 100%IACS 105%IACS 110%*
Tensile Strength450 N/mm²520 N/mm² (+15%)600 N/mm² (+30%)
Corrosion ResistanceStandard coatingEnhanced epoxy coatingCopper-clad steel core

Supplier's note

  1. Technical Breakthroughs:

    • Multi-strand flexibility: Enables tight-space routing without compromising integrity.
    • Copper-clad steel cores: Combine cost efficiency with 20% higher tensile strength than pure copper.
    • Customizable diameter: Tailor wire thickness to match load requirements (e.g., 1.4mm for residential grounding vs. 3.0mm for industrial plants).
  2. Optimal Version Selection:

    • Base Model: Ideal for standard underground cables in low-stress environments.
    • Advanced Model: Suitable for construction sites needing 15% better conductivity and durability.
    • Pro Model: Designed for corrosive or high-load scenarios (e.g., offshore wind turbines), with triple the corrosion resistance of industry benchmarks.

With the Pro version’s copper-clad steel core, you can achieve 30% higher tensile strength than traditional copper wires, ensuring longevity in harsh marine environments. Pair this with its premium conductivity to guarantee reliable grounding even in extreme weather conditions.

Frequently asked questions

  • Which stranded copper wire model is best suited for underground cable applications?

  • What’s the difference between copper and copper-clad steel conductors in stranded ground wires?

  • Can this stranded copper wire be customized for specific diameters or strengths?

  • Is this stranded copper ground wire compliant with electrical safety standards?

  • How should I store stranded copper wire to prevent corrosion?

  • Why choose stranded copper over solid copper for electrical performance?

  • Is this stranded copper wire suitable for lightning rod grounding systems?

  • What makes this stranded copper wire ideal for heavy-duty industrial installations?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Solid Copper Wire (Industry Standard)General electrical wiring, low-flex applications1.4mm diameter, solid core (ASTM B3), conductivity: 58 MS/m (IEC 60228)High conductivity, durable, widely compatible with existing systemsLess flexible (brittle in cold), difficult to bend (▲劣势 vs stranded designs)
Our Base (Copper-Clad Steel)Underground cables, cost-sensitive projects1.4mm diameter, copper-clad steel (ASTM B615), conductivity: 42 MS/m (▲ vs steel core)Cost-effective, corrosion-resistant outer layer (ASTM B117: 500hr salt spray)Lower conductivity than pure copper, heavier (▲劣势 vs stranded copper)
Our Advanced (Stranded Copper)Lightning rods, industrial machinery19-strand copper (ASTM B258), 1.4mm diameter, flexibility: 500+ bend cycles (ASTM B258)▲ Superior flexibility, 58 MS/m conductivity (▲ vs Base), 400 N/mm² tensile strength (ASTM B258)Higher cost, requires careful handling for stranded ends (▲优势 vs solid wires)
Aluminum WireLong-distance power lines1.4mm diameter, conductivity: 37.7 MS/m (IEC 60228), lightweight (▲ vs copper)Lighter, cost-effective for large-scale installationsLower conductivity (▲劣势 vs copper), prone to corrosion without coating
Coated Copper WireHarsh outdoor environmentsPVC coating (ASTM D1729), 1.4mm copper core, UV resistance (ASTM G154)Enhanced environmental protection (▲ vs bare wires), 58 MS/m conductivityLess flexible (▲劣势 vs stranded), added weight from coating
Bare Copper WireDirect grounding systems1.4mm diameter, bare copper (ASTM B1), 58 MS/m conductivityDirect electrical contact (ideal for grounding), corrosion-resistantNo insulation (▲劣势 vs coated wires), requires protective conduit in some uses

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.