Temperature Measurement Range | Industrial furnaces, cryogenics | Industry: -50°C to 1200°C (ISO 5802) Base: -200°C to 1800°C▲ (ASTM E230) Advanced: -200°C to 2000°C▲▲ (ASTM E230) | Covers extreme environments (e.g., aerospace, deep-freeze warehouses) | Advanced requires specialized calibration for ultra-high temps |
Material Composition | Chemical plants, offshore platforms | Industry: Standard steel (ASTM A109) Base: 304 Stainless Steel▲ (ASTM A240) Advanced: 316L Stainless Steel▲▲ (ASTM A276) | Resists corrosion from acids, saltwater, and harsh chemicals | Advanced material adds cost (~20% premium) |
Probe Customization | Custom equipment, field installations | Industry: Fixed probe length (IEC 60751) Base: Adjustable up to 1m + Threaded Mounting▲ (ISO 7000) Advanced: Adjustable up to 2m▲▲ (ISO 7000) | Fits varied equipment sizes and mounting needs (e.g., oil rigs) | Custom lengths may delay delivery by 3–5 days |
Sensor Head Replacement | Pharmaceutical, food processing | Industry: Non-replaceable▲ Base: Fixed head (IEC 60581) Advanced: Quick-swap heads▲▲ (IEC 60581 + proprietary design) | Reduces downtime during maintenance (e.g., bioreactor cleaning) | Advanced requires training to use quick-swap mechanism |
Environmental Resistance | Marine, outdoor installations | Industry: IP54▲ (IEC 60529) Base: IP67▲▲ (IEC 60529) Advanced: IP69K▲▲▲ (IEC 60529) | Withstands high-pressure washdowns and submersion (e.g., offshore platforms) | Advanced sealing may slow thermal response by ~10% |
Brand Reliability & Warranty | Critical infrastructure (power plants) | Industry: 1-year warranty▲ Base: 3-year warranty▲▲ (ISO 9001) Advanced: 5-year + 24/7 support▲▲▲ (ISO 9001 + 17025) | Minimizes replacement costs in high-risk environments | Advanced support increases upfront cost by ~15% |