All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier

High Quality Iso Standard Large Volume Carbon Steel and FRP Underground Fuel Storage tank Design for Gas Stations From China

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • High-Capacity Fuel Storage: Designed to safely store up to 5,000 liters of fuel underground, compliant with ISO standards for gas stations and industrial applications.
  • Durable Material Construction: Built with carbon steel and fiberglass-reinforced plastic (FRP) to ensure corrosion resistance, pressure tolerance, and longevity in harsh environmental conditions.

Key features

  • 1. Corrosion-Resistant Material Technology

  • With corrosion-resistant carbon steel and fiberglass-reinforced polymer (FRP) composite material, ensure long-term durability in harsh underground environments. Up to 30% more corrosion-resistant than single-material tanks

  • 2. Simplified Maintenance Design

  • With a pressure-relief vent and secure access points, simplify maintenance and safety inspections. 50% faster access compared to standard designs

  • 3. High-Capacity Performance

  • With a 5000L large-volume capacity, meet high-demand fuel storage needs for commercial gas stations. 20% higher capacity than industry-standard underground tanks

  • 4. Underground Scenario Optimization

  • With an underground installation design, prevent environmental contamination while ensuring safe, continuous fuel supply for commercial operations. Engineered for 24/7 commercial use.

  • 5. ISO-Standard Compliance

  • With ISO-standard certification, guarantee compliance with international safety and environmental regulations for fuel storage. Meets or exceeds OSHA safety requirements

Product details

High Quality Iso Standard Large Volume Carbon Steel and FRP Underground Fuel Storage tank Design for Gas Stations From China

The LQMC High Quality ISO Standard Underground Fuel Storage Tank combines robust carbon steel and fiberglass reinforced polymer (FRP) materials to deliver durable, safe, and compliant fuel storage solutions for gas stations. Designed with a 5000L capacity and ISO-certified standards, it ensures reliable performance in harsh environmental conditions.

Technical specifications

FeatureSpecificationBenefit
Material CompositionCarbon Steel + Fiberglass Reinforced Polymer (FRP)With dual-layer construction, you can achieve 30% higher corrosion resistance than single-material tanks.
Storage Capacity5000 litersWith 5000L capacity, you can meet the fuel demands of high-traffic gas stations.
Compliance StandardsISO 9001, API 650With ISO certification, you can ensure compliance with global quality standards.
Pressure Resistance2.5 MPaWith 2.5 MPa pressure resistance, you can safely store high-pressure fuels.
Corrosion Resistance10-year warrantyWith a 10-year warranty, you can reduce long-term maintenance costs.

Customization guide

Adjustable material ratios (steel/FRP) to meet specific corrosion resistance needs. Custom color schemes and branding options for corporate identity.

Get inspired

The LQMC High Quality ISO Standard Underground Fuel Storage Tank combines robust construction with advanced materials to ensure safe, long-term fuel storage. Designed for gas stations and industrial facilities, it offers reliable performance in diverse environmental conditions.

Choose your model

ParameterBase ModelAdvanced ModelPro Model
MaterialCarbon SteelCarbon Steel + FRP LiningDual-layer Carbon Steel & FRP Composite
Pressure Resistance2.0 MPa2.5 MPa (+25%)2.6 MPa (+30%)*
Corrosion Resistance5-year warranty8-year warranty10-year warranty
Weight1500 kg1700 kg1900 kg

Supplier's note

  1. Technical Breakthroughs:

    • The Pro Model’s dual-layer material achieves triple the industry-standard corrosion resistance, enabling safe storage of aggressive fuels.
    • The 2.6 MPa pressure resistance exceeds API 650 requirements by 30%, ensuring stability in high-pressure systems.
    • The cylindrical design reduces surface-area-to-volume ratio by 20%, minimizing heat loss for temperature-sensitive contents.
  2. Optimal Version Selection:

    • Pro Model: Ideal for coastal or industrial zones with aggressive chemicals. Its 10-year warranty and marine-grade materials reduce long-term costs.
    • Advanced Model: Suitable for moderate environments needing enhanced durability. The FRP lining extends service life by 60% compared to Base models.
    • Base Model: Cost-effective for standard gas stations with low corrosion risks. Meets all regulatory requirements at an entry-level price.

*30% higher than industry benchmarks for underground fuel tanks.

Frequently asked questions

  • Which underground fuel storage tank model suits small gas stations with limited space?

  • How to clean and maintain the vent cap of an underground fuel tank to prevent clogging?

  • Carbon Steel vs FRP: Which material is better for corrosive underground environments?

  • Can LQMC customize underground fuel tanks for specific capacity or dimensions?

  • Is the LQMC ISO standard tank API-certified for fuel storage safety?

  • How does the cylindrical design of the 5000L tank ensure pressure safety?

  • What makes the LQMC tank suitable for high-traffic gas stations needing 5000L storage?

  • Does the carbon steel and FRP combination prevent environmental leaks?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Material CompositionUnderground fuel storage, chemical tanks- Industry Standard: Basic steel (ASTM A36)
- Our Base: Carbon steel with epoxy coating (ASTM A370)
- Our Advanced: Fiberglass Reinforced Plastic (FRP) (ASTM D790)
▲ Base: 20% lighter than basic steel (e.g., 1.5kg/L)
▲▲ Advanced: Non-conductive and corrosion-free
Base: Requires periodic coating maintenance
Advanced: 30% higher upfront cost
Corrosion ResistanceCoastal regions, chemical storage- Industry Standard: 10 years (generic)
- Our Base: 15 years (ASTM G1)
- Our Advanced: 25 years (ASTM G1 + FRP’s inherent resistance)
▲ Base: 50% longer lifespan than standard
▲▲ Advanced: 100% resistance to saltwater corrosion
Standard: Prone to rust in aggressive environments
CapacityGas stations, industrial facilities- Industry Standard: 3,000–8,000L (ISO 9809)
- Our Base/Advanced: 5,000L (ISO 9809)
▲ Base/Advanced: Precise fit for mid-sized gas stations
▲ Advanced: 20% higher pressure tolerance (EN 1901)
Not scalable for very large facilities (>10,000L)
Leak PreventionHigh-risk zones (e.g., near water sources)- Industry Standard: Single-walled with basic welds (ASME BPVC)
- Our Base: Double-walled + leak detection (API 653)
- Our Advanced: Triple-layer FRP + real-time monitoring
▲ Base: 95% leak detection accuracy
▲▲ Advanced: Zero emissions guarantee (ISO 14001)
Base: Higher installation complexity
Installation DepthRocky terrain, urban areas- Industry Standard: 1.5m burial depth
- Our Base: 1.8m (local codes compliant)
- Our Advanced: 2.0m (enhanced stability)
▲ Base: Meets 80% of global regulations
▲▲ Advanced: 30% deeper burial for safety
Advanced: Requires specialized excavation equipment
Compliance StandardsGlobal deployment- Industry Standard: OSHA/EPA basic compliance
- Our Base: ISO 9001 + API 653
- Our Advanced: ISO 14001 + ATEX Zone 1 certification
▲ Base: 90% regulatory acceptance worldwide
▲▲ Advanced: Approved for hazardous zones (e.g., oil refineries)
Advanced: 50% longer certification process

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.