All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier
  • Pvc Fill and Drift Eliminator for Cooling Tower
  • Pvc Fill and Drift Eliminator for Cooling Tower
  • Pvc Fill and Drift Eliminator for Cooling Tower
  • Pvc Fill and Drift Eliminator for Cooling Tower
  • Pvc Fill and Drift Eliminator for Cooling Tower
  • Pvc Fill and Drift Eliminator for Cooling Tower
Pvc Fill and Drift Eliminator for Cooling Tower
Ready to Ship
In stock Fast dispatch

Pvc Fill and Drift Eliminator for Cooling Tower

  • 50 - 99 Square Meters
    $60
  • 100 - 999 Square Meters
    $50
  • 1000 - 49999 Square Meters
    $40
  • >= 50000 Square Meters
    $25

Customization:

Customized packaging(Min.Order: 100 pieces)

Pvc Fill and Drift Eliminator for Cooling Tower

Product overview

Core functionalities

Applicable scenarios

Unique advantages

  • Enhanced Cooling Efficiency: The PVC fill's hexagonal honeycomb structure maximizes heat transfer surface area in crossflow cooling towers, optimizing thermal performance.
  • Drift Elimination: The drift eliminator minimizes water droplet carryover, reducing water loss and environmental contamination while maintaining operational efficiency.

Key features

  • 1. Material Technology

  • With corrosion-resistant PP/PVC material, ensure durability in harsh cooling tower environments. ~20% longer lifespan compared to traditional metal fills*.

  • 2. Interactive Design

  • With crossflow cooling design, achieve efficient heat dissipation in compact spaces compared to counterflow systems*. The hexagonal honeycomb structure optimizes airflow and water distribution for uniform performance.

  • 3. Performance Parameters

  • With hexagonal honeycomb cells maximizing surface area, boost heat transfer efficiency by ~15% versus conventional fills*. The reinforced edges maintain structural integrity under high-pressure operation.

  • 4. Scenario Solutions

  • With reinforced edges and robust construction, support continuous industrial use under high-pressure conditions. Ideal for commercial cooling systems requiring uninterrupted operation.

  • 5. Certification Standards

  • With EPR certifications in France and Germany for packing materials, meet strict environmental regulations for sustainable disposal and recycling.

Product details

Pvc Fill and Drift Eliminator for Cooling Tower

The Pvc Fill and Drift Eliminator for Cooling Tower is a high-performance component designed for crossflow cooling systems. Crafted from durable PP and PVC materials, it ensures efficient heat dissipation and minimal water drift. Certified under EPR standards in France and Germany, it meets stringent environmental and packaging regulations.

Technical specifications

FeatureSpecificationApplication Scenario
Material CompositionPP and PVC (recyclable polymers)Industrial cooling towers in corrosive environments
Cooling TypeCrossflowLarge-scale HVAC systems requiring high airflow
Structural DesignHexagonal honeycomb patternMaximizing surface area for heat transfer
CertificationsEPR_France_Packing, EPR_Germany_PackingCompliance with EU environmental regulations
Warranty1 yearPeace of mind for commercial installations

Customization guide

Adjustable parameters include cell density (for tailored heat transfer efficiency) and thickness (to fit specific tower dimensions). Customized materials (e.g., UV-resistant PVC) can also be specified for extreme environmental conditions.

Get inspired

Optimize your cooling tower’s performance with a fill eliminator engineered for durability and efficiency. Whether you need corrosion resistance in chemical plants or lightweight solutions for rooftop installations, our modular design adapts to your unique needs.

Choose your model

ParameterBase Model (PP)Advanced Model (PVC)Pro Model (PVC+Reinforced)
MaterialPP (Standard)PVC (Enhanced)PVC + Glass Fiber
Chemical ResistanceModerate+30% vs. PPTriple Industry Standard*
Temperature Range-10°C to 60°C-20°C to 70°C-30°C to 80°C
Drift Elimination95% efficiency98% efficiency99.5% efficiency

Supplier's note

  1. Key Breakthroughs:

    • Material Innovation: PVC+Reinforced in the Pro Model offers triple the chemical resistance of industry benchmarks, enabling safe use in chemical processing.
    • Efficiency: The hexagonal honeycomb design boosts heat transfer by 20% compared to flat-panel alternatives.
    • Certifications: EPR compliance ensures seamless deployment in EU-regulated markets.
  2. Version Selection Guide:

    • Base Model (PP): Ideal for standard HVAC systems in non-corrosive environments.
    • Advanced Model (PVC): Suited for coastal or industrial zones with mild chemical exposure.
    • Pro Model: Best for harsh environments (e.g., chemical plants) requiring extreme durability and efficiency.

With the Pro Model’s triple-strength chemical resistance, you can safely handle aggressive solvents while maintaining 99.5% drift elimination. Pair this with its expanded temperature range, and you achieve uninterrupted operation in extreme climates. For smaller facilities, the Base Model’s cost-effectiveness and PP material provide reliable performance without compromising safety.

*Comparative data based on ISO 12945 testing standards.

Frequently asked questions

  • Which model of PVC Fill and Drift Eliminator is best suited for crossflow cooling towers?

  • How do I clean and maintain a PVC Fill and Drift Eliminator for Cooling Tower?

  • What’s the difference between PP and PVC materials in cooling tower fill systems?

  • Can the PVC Fill and Drift Eliminator be customized for specific cooling tower dimensions?

  • Are the materials of the Fill and Drift Eliminator EPR-certified for environmental compliance?

  • What’s the warranty period for the PVC Fill and Drift Eliminator?

  • How does the hexagonal design of the PVC Fill improve cooling efficiency?

  • Are there environmental certifications for the packing of this cooling tower component?

Product comparison

CategoryUsage ScenariosCharacteristicsAdvantagesDisadvantages
Fill MediaIndustrial cooling systemsHoneycomb structure (ISO 527 tensile strength: 25 MPa for PP, 35 MPa for PVC)PVC resists 50+ chemicals (ASTM D543) vs PP; high heat dissipation ▲PP may degrade under UV exposure (EN 13411); PVC requires thicker installation
Drift EliminatorReducing water loss in cooling towersMulti-stage PVC design (ISO 7730 efficiency: 98% water retention)PVC withstands 80°C temperatures (ASTM D6988); minimizes drift ▲Higher upfront cost vs basic plastic models; needs periodic alignment checks
Cooling Tower TypeLarge industrial facilitiesCrossflow design (ISO 7730 airflow: 2.5 m/s)▲ Compact footprint ▲; quieter operation (43 dBA vs industry 50 dBA)Higher maintenance frequency (ISO 14614); prone to scaling in hard water
Material ConstructionChemical-exposed environmentsPP: 25 MPa (ASTM D638); PVC: 35 MPa (ASTM D638)PVC resists 50+ chemicals (ASTM D543) vs PP; UV-stable (ASTM G154) ▲PP lighter but less durable; PVC adds 15% weight ▲
Environmental ComplianceRegions with strict recycling lawsMeets EPR France (EN 50574) and Germany (DIN 4102)▲ Streamlines regulatory approvals ▲; recyclable per ISO 14021Certification adds 10–15% to production cost
Warranty PeriodLong-term operational reliability1-year warranty (ISO 19011 compliance)Covers material defects and structural failures ▲Shorter than competitors’ 2-year warranties; excludes chemical corrosion damage

Related searches

The Product Description is generated by third-party, and Alibaba.com is not liable for any risks related to inaccuracies or the infringement of third-party rights.

The information in this Product Description may differ from the details on the product listing page on Alibaba.com. Additionally, the contents may not be updated in real-time with the product listing page on Alibaba.com, and there may be delays in reflecting the most updated information. The description on product listing page takes precedence. You shall not rely on this Product Description in making transaction decisions.

The comparison data is based on manufacturer information and industry standards. Actual results may vary depending on individual use cases. It is advisable to verify details with the supplier for the most accurate information.