All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier

About danfoss condensing unit

Types of Danfoss Condensing Units

Danfoss offers a wide range of condensing units designed for various applications and needs.

  • OptiDan

    Fully integrated condensing units featuring the innovative Danfoss ICM control platform. The ICM control platform provides integrated refrigerant management and system optimization capabilities. The OptiDan series units are available in a broad capacity range to cover all commercial refrigeration needs.

  • Pack System

    It is a fully integrated condensing unit consisting of an MT and LT compressor in a common housing. CO2 transcritical integral condensing units represent an efficient and sustainable solution for various commercial applications. The unit employs the natural refrigerant carbon dioxide (CO2), providing an environmentally friendly alternative to synthetic refrigerants.

  • Modular Condensing Unit

    Flexible refrigeration systems tailored to meet specific refrigeration requirements. They provide a wide range of configurations, including options for medium and low temperature, different compressor technologies, and various condenser types.

  • Pack System Combined

    Vapour compression refrigeration system that combines heating and cooling functions within a single unit. This innovative system utilizes a heat pump to extract heat from the environment to meet heating demands while simultaneously providing cooling performance through conventional refrigeration methods.

  • Dedicated Condensing Unit

    Danfoss dedicated condensing units are designed and built specifically for commercial refrigeration applications.

Danfoss Condensing Unit Specification & Maintenance

Specification

The specifications of Danfoss condensing units may vary depending on model types such as sectional, semi-hermetic, and coastal versions as well as different application needs. Below are a few key specifications details to consider:

  • Capacity Range: Danfoss condensing units are available in a range of capacity sizes (typically from small commercial units to large industrial ones) and measured in kW or HP. Business buyers need to choose a suitable one based on the size of the refrigeration system and also the cooling needs.
  • Operating Temperature: Danfoss condensing units can work in different operating temperature ranges. For instance, some can work efficiently in high-temperature environments (around > 10° C) while others can function in low-temperature or freezing environments (around ≤ -18° C). This means that business buyers need to evaluate their refrigeration systems' efficacy and select a suitable Danfoss condensing unit that can meet a particular refrigerant's evaporation temperature.
  • Refrigerant: Danfoss condensing units are available for a variety of refrigerants, including R134a, R404A, R407C, R410A, R513A, R717, etc. These can be used in a range of application scenarios, such as industrial refrigeration, commercial refrigeration, air conditioning, etc. Business buyers need to choose the right type to ensure its function and performance.

Maintenance

To ensure Danfoss condensing units running efficiently and smoothly over a long time, it is very important to conduct regular maintenance to them. Some maintenance tips are as follows:

  • Clean the unit: Regularly remove dust, dirt, and debris from both the interior and exterior of the condensing unit to ensure good airflow and prevent overheating or other potential issues.
  • Check the electrical components: Regularly inspect the condensing unit's electrical components, such as connections, terminals, and contactors, for any signs of corrosion or looseness, ensuring robust electrical connection and reliable control.
  • Check the Freon level: Regularly check the Freon level of the condensing unit. If it's too low, buyers need to find and repair refrigerant leaks first and then add refrigerant to the system.
  • Lubricant oil: Periodically check and replace the lubricant oil of the condensing unit's compressor to ensure proper lubrication and smooth operation.
  • Keep away from flammable items: Remind users to keep the condensing units away from flammable and combustible materials to avoid potential fire hazards.

Scenarios

The Danfoss condensing units are primarily utilized for commercial and industrial refrigeration applications. Below are some usage scenarios for the unit.

  • Supermarkets and Grocery Stores

  • Food Processing and Cold Storage Facilities

  • Restaurants, Bars, and Catering Services

  • Air Conditioning Applications

How to choose Danfoss condensing units

Wholesale business buyers should keep several factors in mind when choosing condensing units for commercial refrigeration systems. These factors to consider include the overall cooling requirements, space constraints, operational efficiency, noise level, and future maintenance and support.

Business buyers should first consider the amount of cooling a condensing unit needs to provide.They can calculate the amount of heat that needs to be removed by the commercial refrigeration system (usually measured in BTUs). They can also consider any external factors that may affect the amount of heat in the commercial refrigeration space - such as the building’s insulation and the amount of sunlight that enters the room. They may need to consult with an expert to determine the exact cooling capacity (measured in horsepower or kilowatts) that must be provided by the condensing unit.

The physical dimensions of the condensing unit are crucial, especially if it will be located indoors in an area where floor or wall space is limited. Business buyers will need to look for compact, space-saving designs such as wall-mounted or remote models.

The operational efficiency of the condensing unit is critical, as it will determine the amount of electricity the unit uses to drive up operating costs. Business buyers should choose condensing units with energy-saving features such as EC fan motors and variable-speed compressors. The unit's energy efficiency rating (EER or SEER) should also be considered when making a selection.

The condensing unit's noise level is an important factor to consider when it is located near occupied areas such as offices, workspaces, or residential buildings. Business buyers should choose units designed for quiet operation with noise-reducing features such as variable-speed motors, sound blankets, and resilient mounts.

Finally, business buyers should consider the future maintenance and support required by the condensing unit. They should choose condensing units manufactured by reliable, globally-recognized brands in the industry with a large network of service providers. This will ensure that qualified technicians are always available to provide installation, repair, or maintenance services. Business buyers should also ensure that the condensing units they choose have easily identifiable and accessible components for speedy servicing.

Q&A

Q: How does Danfoss perform the condensing unit function?

A: The function is performed by using a series of coils and fans designed to dissipate heat from the refrigerant extracted from the coils inside the refrigerator or freezer. As the refrigerant loses heat in the condensing unit, it changes back into a liquid and is pumped back into the system by the refrigerant compressor.

Q: What is the Danfoss condensing unit model?

A: The model is identified by a series of numbers and letters that indicate the unit's design, capacity, voltage, and other specifications. For detailed information on specific models, one can consult Danfoss's product documentation or technical support.

Q: What is the Danfoss KVR condensing unit?

A: This is a small, efficient, and robust refrigeration unit designed for commercial applications such as cold stores, supermarkets, and food processing facilities.

Q: What does a condensing unit do?

A: It changes the vaporized refrigerant back into a liquid by removing heat from the refrigerant, a process known as condensation. It also houses the compressor that pumps the refrigerant throughout the refrigeration system.

Q: What happens if the condensing unit is faulty?

A: If there is any damage or fault in the condensing unit, the refrigerator or freezer will fail to work adequately. This may lead to the loss of food and other perishables.